Industrial Monitoring and Alarms | RACO®

Biological Oxygen Demand: Wastewater Treatment Explained

Written by Admin | May 02 2023

Biological Oxygen Demand: Wastewater Treatment Explained

Biological Oxygen Demand (BOD) is a critical concept in the field of wastewater treatment. It refers to the amount of oxygen that bacteria will consume while decomposing organic matter under aerobic conditions. In simpler terms, BOD is the amount of oxygen required to break down all biological material present in the water. The higher the BOD, the greater the degree of pollution. Understanding this concept is crucial for anyone involved in wastewater treatment, as it directly impacts the efficiency and effectiveness of the treatment process.

This glossary article aims to provide an in-depth understanding of Biological Oxygen Demand, its significance in wastewater treatment, how it is measured, and the methods used to reduce BOD in wastewater. The article will also delve into the implications of high BOD levels and the regulations surrounding it. By the end of this comprehensive guide, you should have a thorough understanding of BOD and its role in wastewater treatment.

Understanding Biological Oxygen Demand

Biological Oxygen Demand is a measure of the quantity of oxygen used by microorganisms (e.g., bacteria) in the oxidation of organic matter. When organic matter decays, oxygen is consumed. Therefore, the more organic material there is in the water, the more oxygen is required for decomposition. This oxygen is not available for other aquatic life, leading to a decrease in the overall oxygen level of the water, which can be harmful or even fatal to aquatic organisms.

BOD is typically measured in milligrams of oxygen consumed per liter of sample during 5 days of incubation at 20 °C and is often used as a surrogate of the degree of organic pollution of water. This measure is known as BOD5. A high BOD indicates the presence of a large amount of organic matter, or pollutants. Conversely, a low BOD signifies a small amount of organic matter, indicating cleaner water.

Importance of BOD in Wastewater Treatment

The BOD level is a significant indicator of the effectiveness of wastewater treatment plants. It is used to gauge the amount of organic matter in wastewater, which in turn determines the amount of oxygen that will be required in the biological treatment process. High BOD levels mean that a large amount of oxygen is needed for the treatment process, which can be costly and time-consuming.

Furthermore, BOD is used to ensure that the treated wastewater released into the environment will not adversely affect aquatic life. High levels of BOD in the discharged water can deplete the oxygen levels in the receiving waters, leading to the death of fish and other aquatic organisms. Therefore, it is crucial to monitor and control the BOD levels in wastewater treatment.

Factors Affecting BOD

Several factors can influence the BOD of wastewater. The type and amount of organic matter present significantly affect the BOD. Wastewater with a high concentration of easily degradable organic matter will have a higher BOD. Additionally, the temperature and pH of the wastewater can also influence the BOD. Microorganisms that break down the organic matter work best at certain temperatures and pH levels, and any changes to these conditions can affect their activity and, consequently, the BOD.

Moreover, the presence of certain substances, such as heavy metals and toxic chemicals, can inhibit the activity of the microorganisms, leading to a lower BOD. On the other hand, nutrients like nitrogen and phosphorus can enhance microbial activity, resulting in a higher BOD. Therefore, the composition of the wastewater plays a crucial role in determining its BOD.

Measuring Biological Oxygen Demand

The standard method for measuring BOD involves taking a water sample and incubating it for five days at 20°C. The amount of oxygen consumed by the microorganisms during this period is then determined and reported as BOD5. This method, however, has its limitations. It is time-consuming, and the results can be influenced by various factors, such as the type and number of microorganisms present and the presence of toxic substances in the water.

Several alternative methods have been developed to overcome these limitations. These include the use of respirometers, which measure the amount of oxygen consumed by the microorganisms directly, and the use of chemical methods, such as the dichromate method, which oxidizes the organic matter in the sample and measures the amount of oxygen consumed in the process. These methods provide faster and more accurate results than the standard BOD5 method.

Standard BOD5 Method

The standard BOD5 method involves taking a sample of the wastewater and diluting it with a known volume of dilution water. The diluted sample is then incubated for five days at 20°C. After the incubation period, the amount of dissolved oxygen in the sample is measured. The difference between the initial and final dissolved oxygen levels represents the BOD5 of the sample.

This method, however, has several limitations. It is time-consuming, taking five days to complete. Furthermore, the results can be influenced by various factors, such as the type and number of microorganisms present in the sample and the presence of toxic substances that can inhibit microbial activity. Despite these limitations, the BOD5 method is widely used due to its simplicity and low cost.

Alternative Methods for Measuring BOD

Due to the limitations of the standard BOD5 method, several alternative methods have been developed. These include the use of respirometers, which measure the amount of oxygen consumed by the microorganisms directly, and the use of chemical methods, such as the dichromate method, which oxidizes the organic matter in the sample and measures the amount of oxygen consumed in the process.

Respirometry is a direct method that measures the oxygen consumption rate of the microorganisms in the sample. This method provides faster results than the BOD5 method and is less influenced by external factors. However, it requires specialized equipment and is more expensive.

The dichromate method is a chemical method that involves the oxidation of the organic matter in the sample with potassium dichromate in an acidic solution. The amount of dichromate reduced is then measured, which is proportional to the BOD. This method is faster and more accurate than the BOD5 method, but it requires the use of hazardous chemicals and does not differentiate between biodegradable and non-biodegradable organic matter.

Reducing BOD in Wastewater

Reducing the BOD in wastewater is a crucial part of the treatment process. High BOD levels can lead to the depletion of oxygen in the receiving waters, causing harm to aquatic life. Therefore, wastewater treatment plants aim to reduce the BOD to acceptable levels before discharging the treated water into the environment.

There are several methods for reducing BOD in wastewater, including physical, chemical, and biological methods. Physical methods involve the removal of solid matter from the wastewater, which reduces the amount of organic matter available for decomposition. Chemical methods involve the use of chemicals to precipitate and remove organic matter from the water. Biological methods involve the use of microorganisms to break down the organic matter, thereby reducing the BOD.

Physical Methods for Reducing BOD

Physical methods for reducing BOD involve the removal of solid matter from the wastewater. This is usually achieved through sedimentation, where the wastewater is allowed to stand in a tank, and the solid matter settles at the bottom. The settled solids, known as sludge, are then removed from the tank. This process reduces the amount of organic matter in the wastewater, thereby reducing the BOD.

Another physical method is filtration, where the wastewater is passed through a filter that removes the solid matter. This method is effective in removing larger particles of organic matter but is less effective in removing smaller particles and dissolved organic matter. Therefore, it is often used in combination with other methods to achieve a greater reduction in BOD.

Chemical Methods for Reducing BOD

Chemical methods for reducing BOD involve the use of chemicals to precipitate and remove organic matter from the wastewater. One common method is coagulation and flocculation, where chemicals are added to the wastewater to cause the organic matter to form larger particles, or flocs, which can then be removed by sedimentation or filtration.

Another chemical method is chlorination, where chlorine is added to the wastewater to oxidize the organic matter, thereby reducing the BOD. However, this method has its drawbacks, as the chlorine can react with the organic matter to form harmful by-products. Therefore, it is usually used as a final disinfection step after the BOD has been reduced by other methods.

Biological Methods for Reducing BOD

Biological methods for reducing BOD involve the use of microorganisms to break down the organic matter in the wastewater. This is the most common method used in wastewater treatment plants. The microorganisms consume the organic matter as food, converting it into carbon dioxide, water, and biomass. This process reduces the BOD of the wastewater.

There are two main types of biological treatment: aerobic and anaerobic. In aerobic treatment, the microorganisms require oxygen to break down the organic matter, so air is bubbled through the wastewater to provide the necessary oxygen. In anaerobic treatment, the microorganisms break down the organic matter in the absence of oxygen, producing methane gas as a by-product. Both methods are effective in reducing BOD, but they require careful control of the operating conditions to ensure optimal performance.

Implications of High BOD Levels

High BOD levels in wastewater can have serious implications for the environment and human health. When wastewater with a high BOD is discharged into a body of water, it can deplete the oxygen levels in the water, leading to the death of fish and other aquatic organisms. This can disrupt the ecosystem and lead to a decline in biodiversity.

Furthermore, high BOD levels can indicate the presence of disease-causing microorganisms in the wastewater, posing a risk to human health. These microorganisms can cause diseases such as cholera, typhoid, and dysentery if they contaminate drinking water supplies. Therefore, it is crucial to reduce the BOD in wastewater to safe levels before it is discharged into the environment.

Impact on Aquatic Life

High BOD levels can have a detrimental effect on aquatic life. When wastewater with a high BOD is discharged into a body of water, the microorganisms in the water consume the organic matter in the wastewater, using up the available oxygen in the process. This can lead to a decrease in the oxygen levels in the water, a condition known as hypoxia. Aquatic organisms, such as fish and invertebrates, require oxygen to survive, so a decrease in oxygen levels can lead to their death.

Furthermore, the decomposition of the organic matter can lead to the production of ammonia, which is toxic to aquatic life. High levels of ammonia can cause fish kills and other adverse effects on aquatic organisms. Therefore, it is crucial to reduce the BOD in wastewater to prevent harm to aquatic life.

Impact on Human Health

High BOD levels can also pose a risk to human health. Wastewater with a high BOD often contains disease-causing microorganisms, such as bacteria, viruses, and parasites. These microorganisms can cause diseases such as cholera, typhoid, and dysentery if they contaminate drinking water supplies.

Furthermore, the decomposition of organic matter in wastewater can produce harmful gases, such as methane and hydrogen sulfide, which can pose a risk to human health if they are inhaled. Therefore, it is crucial to treat wastewater to reduce the BOD and remove harmful microorganisms before it is discharged into the environment.

Regulations Surrounding BOD

Due to the potential environmental and health impacts of high BOD levels, there are strict regulations in place to control the BOD in wastewater. These regulations vary by country and region, but they generally require wastewater treatment plants to reduce the BOD to a certain level before the wastewater can be discharged into the environment.

For example, in the United States, the Environmental Protection Agency (EPA) sets effluent guidelines for various industries, specifying the maximum allowable BOD levels in the discharged wastewater. These guidelines are designed to protect the quality of the receiving waters and to prevent harm to aquatic life and human health. Failure to comply with these guidelines can result in fines and other penalties.

Effluent Guidelines

Effluent guidelines are standards set by regulatory bodies that limit the amount of pollutants, including BOD, that can be discharged from various industrial sources into bodies of water. These guidelines are based on the performance of treatment and control technologies and are designed to minimize the impact of wastewater discharge on the environment.

In the United States, the EPA sets effluent guidelines for various industries. These guidelines specify the maximum allowable levels of various pollutants, including BOD, in the discharged wastewater. The guidelines are enforced through permits issued under the National Pollutant Discharge Elimination System (NPDES), and facilities that fail to meet the specified limits can face penalties.

Monitoring and Compliance

Monitoring and compliance are crucial aspects of BOD regulations. Wastewater treatment plants are required to regularly monitor the BOD levels in their discharged wastewater to ensure compliance with the effluent guidelines. This is usually done through sampling and laboratory testing.

If a facility is found to be in violation of the effluent guidelines, it can face penalties, including fines and enforcement actions. In severe cases, the facility may be required to upgrade its treatment process to achieve the necessary BOD reduction. Therefore, it is crucial for facilities to have effective wastewater treatment processes in place to ensure compliance with BOD regulations.

Conclusion

Biological Oxygen Demand is a crucial concept in wastewater treatment. It measures the amount of oxygen required to break down the organic matter in the water, serving as an indicator of the degree of pollution. High BOD levels can have serious implications for the environment and human health, leading to the depletion of oxygen in the water, harm to aquatic life, and the spread of disease-causing microorganisms.

Therefore, it is crucial to reduce the BOD in wastewater to safe levels before it is discharged into the environment. This can be achieved through various methods, including physical, chemical, and biological treatment. Furthermore, there are strict regulations in place to control the BOD in wastewater, and wastewater treatment plants are required to monitor and comply with these regulations to prevent harm to the environment and human health.